Quick contact info

Welcome to Ahmed Construction Company – your partner for innovative and high-quality construction. From residential to commercial projects, we turn dreams into reality with precision and reliability. Building a future of excellence, one project at a time.

Monday to Saturday: 9:00 AM to 6:00 PM Office 2, 3rd Floor, Bigcity Plaza, Gulberg-III, Lahore +92-322-8000190 +92-322-8000190 info@acco.com.pk
Worked with ACCO?Scan to share your experience on Google.
Review us on Google →

Healthcare Facility Design Standards 2026-27: Hospitals, Clinics & Labs in Pakistan

Healthcare Facility Design Standards 2026-27: Hospitals, Clinics & Labs in Pakistan

Healthcare Facility Design Standards 2026-27: Hospitals, Clinics & Labs in Pakistan

By , CEO, Ahmed Construction Company (ACCO) · Updated · Reviewed by ACCO architects and engineers

Since 1998Design and construction in Lahore
Based in Gulberg-IIIHead office in Lahore
Architects + EngineersArchitecture, structure and MEP in-house
Free DrawingsOn award of construction

Quick Answer

Healthcare facility design standards 2026-27 for hospitals, clinics and labs in Pakistan: PHC licensing, building codes, HVAC, fire, medical gases and layout. Ahmed Construction Company (ACCO), based in Gulberg-III Lahore since 1998, provides hospital design & construction services with design drawings free on award of construction.

Healthcare facility design standards set the minimum requirements that hospitals, clinics and laboratories must meet to keep patients and staff safe. In Pakistan there is no single rulebook that covers everything. Instead, owners and designers combine national building codes, provincial healthcare commission requirements, local development authority by-laws and recognised international standards for ventilation, fire safety, medical gases and radiation protection. Understanding how these fit together is essential before design starts, because changing a layout after construction is expensive and can delay licensing. This guide summarises the healthcare facility design standards most relevant in 2026-27 for hospitals, clinics and diagnostic laboratories in Pakistan, explains what each covers, and shows how to apply them in practice.

Healthcare Facility Design Standards at a Glance

Building approvalLocal development authority, municipal body or cantonment board, such as LDA in Lahore or DHA within its schemes
Facility licensingProvincial healthcare commissions, such as the Punjab Healthcare Commission and its Minimum Service Delivery Standards
Structure and buildingBuilding Code of Pakistan (PEC), including seismic provisions
Fire and life safetyBuilding Code of Pakistan fire safety provisions and NFPA standards widely used for healthcare
VentilationASHRAE 170 for healthcare ventilation
Medical gasesHTM 02-01 or NFPA 99 principles
RadiationPakistan Nuclear Regulatory Authority requirements for X-ray, CT and other radiation facilities
Infection preventionWHO infection-prevention and control guidance

Why Design Standards Matter

Standards are not paperwork. They encode lessons learned from fires, outbreaks, earthquakes and clinical errors. A facility designed to them is safer, easier to license and easier to operate. Ignoring them usually leads to one of three outcomes: rejection at licensing, expensive changes after construction, or a building that is unsafe to use. In Pakistan, growing private healthcare investment and stricter enforcement by healthcare commissions mean owners can no longer treat standards as optional.

1. Planning and Layout Standards

Zoning and flows

Good healthcare layouts separate public, clinical, support and service zones. Patients, visitors, staff, clean supplies, dirty linen, waste and bodies should move on separate routes where possible. Emergency and imaging should be close to each other, theatres close to ICU and CSSD, and wards linked to theatres by bed lifts.

Space standards

Rooms need enough space for staff to work around the patient and for equipment. Bed spacing in wards, clearances around ICU beds and theatre tables, and corridor widths for bed movement are core requirements. Doors must be wide enough for beds and trolleys.

Accessibility

Ramps, accessible toilets, lifts and clear signage are needed for patients with limited mobility, wheelchairs and stretchers.

2. Structural and Seismic Standards

The Building Code of Pakistan sets structural design requirements, including seismic zoning. Hospitals are essential facilities that should remain usable after an earthquake, so higher performance is appropriate. Non-structural elements such as ceilings, partitions, pipes, ducts and heavy equipment must be braced, because their failure can close a hospital even when the frame survives.

3. Fire and Life Safety Standards

Hospital patients may be unable to move, so evacuation relies on horizontal movement to protected compartments rather than immediate use of stairs. Key requirements include fire compartments with rated walls and doors, smoke control, automatic detection and alarm, sprinklers where required, protected escape routes and emergency lighting. Oxygen-rich environments around medical gas outlets add risk and must be considered.

4. HVAC and Ventilation Standards

Ventilation controls infection as well as comfort. ASHRAE 170 sets air-change rates, filtration, temperature, humidity and pressure relationships for healthcare spaces.

SpacePressure relationshipMain ventilation requirements
Operation theatrePositive to surroundingsHigh air changes, HEPA or high-grade filtration, humidity control
Airborne isolation roomNegative to corridorExhaust to outside, anteroom where required
Protective isolationPositiveHigh-grade filtration for immunocompromised patients
ICUBalanced or as designedElevated air changes, filtration
LaboratoryNegative in many areasExhaust, fume cupboards and biosafety cabinets as needed
Dirty utility / sluiceNegativeExhaust to prevent odour and contamination spread

5. Electrical and Power Standards

Power cuts are common in Pakistan, so hospitals need standby generators with automatic transfer, UPS for critical loads, separate essential circuits and, in theatres and ICUs, isolated power systems with monitoring. Earthing and equipotential bonding protect patients connected to electrical equipment.

6. Medical Gas Standards

Oxygen, vacuum, medical air and anaesthetic gases need duplicated sources, area alarms, zone valve boxes and correctly specified pipework installed and tested by trained specialists. See our guide to medical gas pipeline systems to HTM 02-01.

7. Infection-Control Finishes

Clinical areas need seamless, non-porous, cleanable floors with coving, washable or clad walls, sealed ceilings in clean areas and hands-free fittings. Hand-wash stations must be placed where care happens. See hygienic materials for OT and ICU.

8. Waste and Water

Hospital waste must be segregated, stored and disposed of under provincial hospital waste management rules. Designs need dedicated waste rooms, separate routes and, for larger facilities, arrangements for treatment. Water systems require storage, treatment and, for dialysis and sterilisation, specially treated water.

9. Vertical Transport and Access

Multi-storey hospitals depend on lifts. Standards and good practice call for at least one bed lift large enough for a patient bed with staff and equipment, with separate lifts for visitors and, in larger hospitals, for services such as food, linen and waste. Fire-fighting and evacuation lifts may be required in tall buildings. Lift lobbies should not block corridors, and lift capacity must be planned for peak visiting hours.

10. Key Department Requirements

Emergency department

Covered ambulance bay, separate walk-in entrance, triage close to arrival, resuscitation bays with full medical gas and power, and direct links to imaging.

Operation theatres

Controlled zones from unrestricted to sterile, scrub areas, recovery, sterile stores and a clear route to CSSD. See our article on ICU and operation theatre design standards.

ICU

Adequate space around each bed, central nursing observation, isolation rooms, pendants for gases and power, and natural light where possible.

Maternity and neonatal units

Labour rooms with privacy, a theatre for caesarean sections nearby, newborn resuscitation areas and secure neonatal units with access control.

Standards by Facility Type

Hospitals

Full set of planning, structural, fire, HVAC, electrical, medical gas, radiation and waste standards, with redundancy for critical services.

Clinics and day-care centres

Accessible layout, infection-control finishes, adequate ventilation, safe electrical systems and procedure rooms suited to the services offered.

Diagnostic laboratories

Separated specimen reception, testing and clean areas, exhaust and biosafety cabinets matched to risk, chemical-resistant surfaces, emergency showers and eyewash.

Imaging centres

Radiation shielding designed and approved for each room, equipment structural loads, cooling and power quality.

How to Apply Standards in a Project

1. Define services

The services offered decide which standards apply.

2. Check licensing requirements

Review the healthcare commission’s requirements for your category of facility.

3. Prepare room data sheets

Record space, finishes, services and equipment for every room.

4. Coordinate design

Architecture, structure and MEP are designed together, ideally in BIM.

5. Test and document

Commission every system and keep records for inspection.

Common Compliance Failures

  • Converting houses or commercial buildings into hospitals without checking structure, fire escapes and lift access
  • Operation theatres without proper air handling or pressure control
  • Missing or poorly placed hand-wash stations
  • Inadequate generator capacity or no UPS for critical equipment
  • X-ray rooms built without approved shielding design
  • No dedicated waste storage or routes

How ACCO Applies These Standards

ACCO, based in Gulberg-III, Lahore since 1998, designs and builds hospitals, clinics and laboratories with these standards built into the brief from the first meeting. Our approach is described in modern hospital construction techniques in Pakistan, and our full offer is on the hospital construction contractor page. For new projects, a feasibility study confirms which standards apply before design begins.

Frequently Asked Questions

Which standards apply to hospitals in Pakistan?

The Building Code of Pakistan, local authority by-laws, provincial healthcare commission requirements, and international standards such as NFPA for fire, ASHRAE 170 for ventilation and HTM 02-01 or NFPA 99 for medical gases. Radiation facilities must meet PNRA requirements.

Who licenses healthcare facilities in Punjab?

The Punjab Healthcare Commission registers and licenses healthcare establishments in Punjab. Other provinces have their own commissions or authorities.

Can a house be converted into a clinic?

Sometimes, for small clinics, subject to zoning, approvals and licensing. The structure, fire escape, accessibility, ventilation and services must be checked first.

What do labs need beyond a normal building?

Separated work areas, exhaust ventilation and biosafety cabinets matched to risk, chemical-resistant surfaces, emergency showers and safe waste handling.

Do clinics need generators?

Any facility with critical equipment, such as procedure rooms, refrigerators for vaccines or diagnostic equipment, should have reliable backup power.

Can ACCO help with licensing requirements?

Yes. ACCO designs to the relevant healthcare commission requirements and prepares documentation to support licensing.

Conclusion

Healthcare facility design standards in Pakistan come from several sources, but together they describe a safe, workable building. Identify the services first, check licensing requirements, coordinate design across all disciplines and test every system before opening. Facilities built this way pass inspection more easily and serve patients better for decades. Call ACCO on 0322-8000190 to discuss your project.

Contact ACCO

Planning a Project with ACCO?

Architecture, engineering and construction from one Lahore team since 1998. Design drawings are free when ACCO is awarded the construction.

Discuss Your ProjectWhatsApp +92 322 8000190

Tanveer Ahmed is the CEO of Ahmed Construction Company (ACCO), a Lahore-based architecture, engineering and construction firm operating since 1998. He has led ACCO since 2005, delivering hospital projects such as LDMC, MCH Islamkot and work at King Edward Medical University / Mayo Hospital and UOL Hospital Lahore, along with residential construction in DHA and Bahria Town, commercial buildings, MEP systems and turnkey projects across Pakistan.

WhatsApp