Quick contact info

Welcome to Ahmed Construction Company – your partner for innovative and high-quality construction. From residential to commercial projects, we turn dreams into reality with precision and reliability. Building a future of excellence, one project at a time.

Monday to Saturday: 9:00 AM to 6:00 PM Office 2, 3rd Floor, Bigcity Plaza, Gulberg-III, Lahore +92-322-8000190 +92-322-8000190 info@acco.com.pk
Worked with ACCO?Scan to share your experience on Google.
Review us on Google →

Operation Theatre Design & Construction in Pakistan: A Complete Guide

Operation Theatre Design & Construction in Pakistan: A Complete Guide

Operation Theatre Design & Construction in Pakistan: A Complete Guide

By , CEO, Ahmed Construction Company (ACCO) · Updated · Reviewed by ACCO architects and engineers

Since 1998Design and construction in Lahore
Based in Gulberg-IIIHead office in Lahore
Architects + EngineersArchitecture, structure and MEP in-house
Free DrawingsOn award of construction

Quick Answer

Operation theatre design and construction in Pakistan: OT zoning, HVAC and laminar flow, medical gases, finishes, power backup, modular OTs and commissioning. Ahmed Construction Company (ACCO), based in Gulberg-III Lahore since 1998, provides hospital design & construction services with design drawings free on award of construction.

Operation theatre design and construction in Pakistan demands more precision than almost any other part of a hospital. The operation theater (OT) is where infection risk, clinical pressure and technical complexity all come together: the air must be clean and correctly pressurised, the power must never fail, gases must flow to every pendant, and surfaces must survive constant disinfection. This guide explains how a modern OT suite is planned, which engineering systems it needs, how finishes and equipment are chosen, and how the work is built, tested and handed over.

Operation Theatre Design and Construction at a Glance

OT suite zonesUnrestricted, semi-restricted and restricted zones, with separate clean and dirty routes
Key systemsDedicated HVAC with HEPA filtration and positive pressure, medical gas pipeline, UPS and generator backup, isolated power where required, surgical lighting and pendants
Key referencesASHRAE 170 ventilation, NFPA 99 health care facilities, WHO infection prevention and control
Licensing (Punjab)Punjab Healthcare Commission standards for surgical facilities
PricingItemised BOQ per project; see the hospital construction cost guide

Planning the OT Suite

A single theatre cannot be designed in isolation. It is part of a suite that includes reception, changing rooms, pre-operative holding, scrub areas, sterile stores, recovery, and dirty utility. The suite must also connect efficiently to the rest of the hospital.

Location in the hospital

  • Close to ICU and the emergency department for critically ill patients
  • Direct link to CSSD for sterile instruments, with separate return of used items
  • Away from public circulation and heavy traffic
  • Bed lifts sized for a bed, equipment and staff

Number and type of theatres

The number of theatres depends on the surgical specialties, expected case load and operating hours. Specialties such as orthopaedics, cardiac and neurosurgery need larger rooms for equipment and imaging. Hybrid theatres with fixed imaging need even more space and structural support.

Zoning and Flow

OT suites are divided into zones with increasing levels of cleanliness. Staff change into theatre clothing before entering the semi-restricted zone, and masks and sterile gowns are required in the restricted zone.

Unrestricted

Reception, family waiting, offices and changing room entry. Street clothes allowed.

Semi-restricted

Corridors, holding, recovery, sterile stores and staff areas. Theatre clothing required.

Restricted

Operating rooms and scrub areas. Full surgical attire and masks required.

Clean supplies, patients, staff and waste should move without crossing unnecessarily. Single-corridor and double-corridor layouts each have advantages; the choice depends on the site and the hospital’s processes. Our guide to patient flow in hospital design explains these principles.

HVAC: The Most Critical System

Clean, filtered and correctly pressurised air is the foundation of infection control in the operation theatre.

  • Dedicated air handling: each theatre or group of theatres served by its own air handling unit, not shared with general areas.
  • High-efficiency filtration: terminal HEPA filters in the ceiling above the operating table.
  • Positive pressure: air flows out of the theatre towards less clean areas, never inwards.
  • Air change rates, temperature and humidity: set according to recognised standards such as ASHRAE 170.
  • Unidirectional (laminar) flow: commonly specified for orthopaedic implant and similar surgery.

Pakistan’s hot, dusty summers and humid monsoon seasons put heavy demands on OT air handling units. Pre-filters, dehumidification and standby capacity should be designed for these conditions. Our guide to hospital HVAC and infection control covers the details.

Medical Gases and Pendants

Each theatre typically needs oxygen, medical air, vacuum, nitrous oxide and, for some procedures, surgical air or carbon dioxide, along with an anaesthetic gas scavenging system. Gases are usually delivered through ceiling-mounted pendants that also carry power and data. Pipelines need zone valves outside each theatre and alarms at the nurse station. Design and installation should follow recognised standards such as HTM 02-01 or NFPA 99; see our medical gas pipeline guide.

Electrical Systems and Power Backup

A power interruption during surgery is dangerous. OT electrical design should include:

  • Supply from essential circuits backed by automatic-start generators
  • UPS for surgical lights, anaesthesia machines, monitors and critical sockets
  • Isolated power supply systems where required by the clinical team and applicable standards
  • Equipotential earthing for patient safety
  • Adequate sockets on pendants and walls, clearly identified by supply type

Finishes, Doors and Ceilings

Every surface in a theatre must be smooth, non-porous, seamless and resistant to cleaning chemicals.

Walls

Options include modular OT wall panels (steel, aluminium-composite or HPL), antibacterial PVC cladding, or specialised hygienic coatings. Joints should be sealed and corners coved.

Floors

Welded sheet vinyl, including antistatic or conductive grades where specified, or seamless epoxy and polyurethane systems. Skirting is coved up the wall to remove dust traps. See our hospital flooring guide.

Ceilings and doors

Sealed, walk-on or clip-in hygienic ceilings that hold the HEPA diffuser and pendants. Hermetically sealed sliding doors reduce air leakage and are often automatic or touch-free. Vision panels allow staff to look in without opening the door.

Our guide to hygienic materials for OT and ICU compares these products.

Supporting Spaces in the OT Suite

Theatres work only as well as the rooms around them. When supporting spaces are cut to save area, equipment ends up in corridors, patients wait in unsuitable places and clean and dirty items mix.

Pre-operative holding

A calm area where patients are checked, prepared and wait for surgery, with oxygen, suction and monitoring at each bay, visible from a staff station.

Scrub stations

Located immediately outside each theatre, with hands-free taps, deep basins designed to reduce splashing, and space for staff to scrub without blocking the corridor. A vision panel lets the team see into the theatre while scrubbing.

Post-anaesthesia recovery

Recovery bays need full monitoring, medical gases and clear observation, as patients wake from anaesthesia here. The number of bays is set by the number of theatres and the type of surgery.

Sterile store and equipment bay

Sterile instruments and consumables need a clean, dry and controlled store within the semi-restricted zone, close to the theatres. Portable equipment such as C-arms and microscopes needs its own parking bay with charging points.

Dirty utility and disposal

Used instruments return to CSSD on a separate route or through a pass-through, and clinical waste leaves the suite without passing through clean areas.

Staff facilities

Separate male and female changing rooms with lockers and showers, a staff rest room and a doctors’ room. These spaces help surgical teams work long lists safely.

Modular OT vs Conventional OT

FactorConventional (masonry and paint)Modular OT panels
HygieneJoints and paint can crack over timeSealed, seamless surfaces designed for disinfection
Installation timeLonger wet work and curingFaster dry installation
IntegrationServices cut into walls on sitePrefabricated panels for control panels, X-ray viewers and storage
Initial costUsually lowerUsually higher
MaintenanceRepainting and repairs neededPanels can be replaced individually

Equipment and Lighting

Operating tables, surgical lights, pendants, anaesthesia machines, monitors and imaging equipment must be coordinated with the ceiling layout, structure and HVAC diffuser. Surgical lights and pendants need structural support above the ceiling, designed for their weight and movement. General room lighting should be bright, glare-free and controllable, and an OT control panel typically shows temperature, humidity, pressure, gas alarms and time.

Upgrading Existing Operation Theatres

Many Pakistani hospitals have older theatres with window air conditioners, painted walls and no pressure control. These can often be upgraded within the existing structure, but limitations on ceiling height, plant space and power capacity must be checked first. Work is usually phased so that some theatres keep running. Our article on why hospitals need modern operation theatre renovation explains the case for upgrading.

How an OT Project Is Delivered

Brief and survey

Specialties, theatre numbers, equipment list and site survey.

Design and BOQ

Coordinated layout, HVAC, gases and electrical design with an itemised BOQ.

Construction

Civil work, services, panels, ceilings, doors and finishes under strict cleanliness control.

Validation

Air balancing, pressure checks, particle counts, gas certification and power testing.

Common Operation Theatre Design Mistakes

  • Sharing an air handling unit between theatres and general areas
  • Ceiling diffusers too small or poorly positioned over the table
  • No anaesthetic gas scavenging
  • Missing or undersized sterile store and dirty utility
  • Tiled walls and floors with grout joints
  • Skipping validation tests before the OT is used

Frequently Asked Questions

What is the most important system in an operation theatre?

The HVAC system, because it controls air cleanliness, pressure, temperature and humidity, which are central to infection control during surgery.

Is a modular OT better than a conventional OT?

Modular OTs offer better hygiene, faster installation and easier maintenance, but usually cost more initially. The choice depends on budget, programme and the type of surgery.

Do all theatres need laminar flow?

No. Unidirectional airflow is commonly specified for orthopaedic implant and some other high-risk surgery. General theatres can use conventional filtered ventilation designed to recognised standards.

Can an old OT be upgraded without closing the hospital?

Usually, yes. Work is phased theatre by theatre with temporary partitions and dust control, so other theatres continue operating.

What tests are done before an OT is used?

Air flow and pressure checks, particle counts, temperature and humidity checks, medical gas testing and purity checks, electrical safety tests and generator changeover tests.

Does ACCO build operation theatres?

Yes. ACCO designs, builds and upgrades operation theatres as standalone projects or within complete hospital construction, priced through an itemised BOQ.

Conclusion

Good operation theatre design and construction depends on careful zoning, dedicated HVAC, reliable medical gases and power, cleanable finishes and thorough validation. Each element supports patient safety, and each is far easier to get right during design than to fix later. Hospitals planning a new OT suite or an upgrade should involve their surgeons, anaesthetists and nurses from the first drawing.

Contact ACCO

Planning a Project with ACCO?

Architecture, engineering and construction from one Lahore team since 1998. Design drawings are free when ACCO is awarded the construction.

Discuss Your ProjectWhatsApp +92 322 8000190

Tanveer Ahmed is the CEO of Ahmed Construction Company (ACCO), a Lahore-based architecture, engineering and construction firm operating since 1998. He has led ACCO since 2005, delivering hospital projects such as LDMC, MCH Islamkot and work at King Edward Medical University / Mayo Hospital and UOL Hospital Lahore, along with residential construction in DHA and Bahria Town, commercial buildings, MEP systems and turnkey projects across Pakistan.

WhatsApp